Evaluation of the accuracy of light polymerizing tray material for splinting in open tray implant impressions: An In-vitro 3D Spatial Analysis.
Abstract
Aims and objective: Precise reproduction of the intra-oral spatial relationship of implants with an impression becomes the first step in achieving an accurate, passively fitting prosthesis. This in vitro study aims to compare the dimensional accuracy of dental implants in casts obtained from open tray splinted implant impression techniques using two different splinting materials.
Methods and Material: A mandibular acrylic model with four implant analogues was used as a reference model. Open tray impression copings were attached to the implant analogues and were splinted using two different materials. Group I-splinted with pattern resin, sectioned and re-joined and Group II- splinted with light cure tray material. Eight polyether impressions were made for each group and poured in type IV dental stone. The casts retrieved from each group were three-dimensionally analysed using coordinate measuring machine with 0.001 mm accuracy. A one-way ANOVA and post hoc test was done to calculate the statistically significant difference between the groups.
Results: The present study revealed no significant difference in the inter-implant distances obtained from pattern resin splinted group, whereas, significant difference in z-axis was found in light polymerising tray resin splinted group when compared to the values obtained from the reference model.
Conclusions: Casts obtained from splinting the impression copings using pattern resin before making implant impression were found to be more accurate than splinting with light cure tray material.
References
2. Tarib NA, Seong TW, Chuen KM, Kun MS, Ahmad M, Kamarudin KH. Evaluation of splinting implant impression techniques: two dimensional analyses. Eur J Prosthodont Restor Dent. 2012;20(1):35.
3. Buzayan M, Baig MR, Yunus N. Evaluation of accuracy of complete-arch multiple-unit abutment-level dental implant impressions using different impression and splinting materials. Int J Oral Maxillofac Implants. 2013;28(6).
4. Aguilar ML, Elias A, Vizcarrondo CE, Psoter WJ. Analysis of three-dimensional distortion of two impression materials in the transfer of dental implants. J Prosthet Den. 2010;103(4):202-9
5. Reddy S, Prasad K, Vakil H, Jain A, Chowdhary R. Accuracy of impressions with different impression materials in angulated implants. Niger J Clin Pract 2013;16(3):279-84.
6. Lee SJ, Cho SB. Accuracy of five implant impression technique: effect of splinting materials and methods. J Adv Prosthodont. 2011;3(4):177-85.
7. Cabral LM, Guedes CG. Comparative analysis of 4 impression techniques for implants. Implant Dent 2007;16(2):187-94.
8. Rutkunas V, Ignatovic J. A technique to splint and verify the accuracy of implant impression copings with light-polymerizing acrylic resin. J Prosthet Den. 2014;111(3):254-6.
9. Papaspyridakos P, Benic GI, Hogsett VL, White GS, Lal K, Gallucci GO. Accuracy of implant casts generated with splinted and non‐splinted impression techniques for edentulous patients: an optical scanning study. Clin Oral Implants Res. 2012;23(6):676-81.
10. Buzayan M, Baig MR, Yunus N. Evaluation of accuracy of complete-arch multiple-unit abutment-level dental implant impressions using different impression and splinting materials. International Journal of Oral & Maxillofacial Implants. 2013;28(6).
11. Selvaraj S, Dorairaj J, Mohan J, Simon P. Comparison of implant cast accuracy of multiple implant impression technique with different splinting materials: An in vitro study. The Journal of the Indian Prosthodontic Society. 2016;16(2):167.
12. Walker MP, Ries D, Borello B. Implant Cast Accuracy as a Function of Impression Techniques and Impression Material Viscosity. International Journal of Oral & Maxillofacial Implants. 2008;23(4).
13. Hariharan R, Shankar C, Rajan M, Baig MR, Azhagarasan NS. Evaluation of accuracy of multiple dental implant impressions using various splinting materials. Int J Oral Maxillofac Implants 2010;25(1)
14. Hsu CC, Millstein PL, Stein RS. A comparative analysis of the accuracy of implant transfer techniques. J Prosthet Den. 1993;69(6):588-93.
15. Selvaraj S, Dorairaj J, Mohan J, Simon P. Comparison of implant cast accuracy of multiple implant impression technique with different splinting materials: An in vitro study. J Indian Prosthodont Soc. 2016;16(2):167.
16. Joseph TM, Ravichandran R, Lylajam S, Viswabharan P, Janardhanan K, Rajeev S. Evaluation of positional accuracy in multiple implants using four different splinting materials: An in vitro study. J Indian Prosthodont Soc 2018;18(3):239.
17. Assif D, Nissan J, Varsano I, Singer A. Accuracy of implant impression splinted techniques: effect of splinting material. Int J Oral Maxillofac Implants 1999;14(6).
18. Kurtulmus-Yilmaz S, Ozan O, Ozcelik TB, Yagiz A. Digital evaluation of the accuracy of impression techniques and materials in angulated implants. J Dent. 2014;42(12):1551-9.
19. Gibbs SB, Versluis A, Tantbirojn D, Ahuja S. Comparison of polymerization shrinkage of pattern resins. J Prosthet Den. 2014;112(2):293-8.