COMPARATIVE EVALUATION OF THE EFFICACY OF DIFFERENT RETREATMENT FILE SYSTEMS WITH OR WITHOUT SOLVENT IN REMOVING OBTURATION MATERIALS FROM ROOT CANALS: AN IN-VITRO CBCT STUDY
Abstract
Abstract:
Background: Complete elimination of the existing root filling is fundamental to successful endodontic retreatment.
Aims: To compare three rotary retreatment systems for removal of gutta-percha and bioceramic sealer, with and without xylene.
Materials and Methods: Forty-two extracted human mandibular premolars with single straight canals were shaped with ProTaper Universal rotary files up to F3 and obturated by the single-cone technique using matched ProTaper gutta-percha and CeraSeal RC bioceramic sealer. After storage, specimens were randomly allotted to six groups (n=7): ProTaper Universal Retreatment, HyFlex Remover and MicroMega Remover, each employed with or without xylene. Residual filling material was quantified from pre- and post-retreatment CBCT scans in axial, coronal and sagittal sections.
Statistical analysis used: Two-way ANOVA with post hoc multiple comparisons (GraphPad Prism 10.1.2); P<0.05.
Results: Xylene significantly lowered the residual material (P=0.0025), and a significant interaction between file system and solvent use was recorded (P<0.0001). HyFlex Remover and ProTaper Universal Retreatment left less residue than MicroMega Remover, the difference being widest when no solvent was used.
Conclusions: None of the systems removed the filling completely. Xylene improved removal with all three systems, HyFlex Remover being most efficient, followed by ProTaper Universal Retreatment and MicroMega Remover.
References
2. Arul B, Varghese A, Mishra A, Elango S, Padmanaban S, Natanasabapathy V. Retrievability of bioceramic-based sealers in comparison with epoxy resin-based sealer assessed using microcomputed tomography: a systematic review of laboratory-based studies. J Conserv Dent Endod. 2021;24:421-34.
3. Dursun PH, Sevimay FS, Buyuksungur A, Celikten B. Evaluation of the effectiveness of MicroMega Remover, ProTaper Universal Retreatment, Reciproc, and Hedstrom files in the retreatment of curved root canals obturated with different techniques: a micro-computed tomography study. Medicina (Kaunas). 2026;62:188.
4. Karunakar P, Reddy MR, Karteek BS, Reddy CL, Swetha C, Racha K, et al. Evaluation of the efficacy of Neo-endo, Hyflex re-treatment file systems and H-files for removing gutta-percha from root canal treated tooth by using stereomicroscope: an in vitro study. J Pharm Bioallied Sci. 2024;16 Suppl 2:S1695-9.
5. Singh ND, Nair R, Maurya N, Jain R, Kumbhare AR, Maloo L. Comparative evaluation of retreatability of three different bioceramic sealers using xylene in root canal retreatment: an in vitro cone-beam computed tomography analysis. J Conserv Dent Endod. 2025;28:687-92.
6. Patel S, Brown J, Semper M, Abella F, Mannocci F. European Society of Endodontology position statement: use of cone beam computed tomography in Endodontics. Int Endod J. 2019;52:1675-8.
7. Arikatla SK, Chalasani U, Mandava J, Yelisela RK. Interfacial adaptation and penetration depth of bioceramic endodontic sealers. J Conserv Dent Endod. 2018;21:373-7.
8. Peña-Bengoa F, Abarca J, Cáceres C, Steinfort K, Niklander SE, Silva EJ. Evaluation of the retreatability and different supplementary cleaning techniques for removing bioceramic sealers in oval-shaped canals. Aust Endod J. 2025;51:723-31.
9. Pirani C, Iacono F, Zamparini F, Generali L, Prati C. Retreatment of experimental carrier-based obturators with the remover NiTi instrument: evaluation of apical extrusion and effects of new kinematics. Int J Dent. 2021;2021:2755680.
10. Generali L, Veneri F, Cavani F, Checchi V, Bertoldi C, Ingrosso AL, et al. Quantitative assessment of apically extruded debris during retreatment procedures using three nickel-titanium rotary systems: an in vitro comparative study. Dent J (Basel). 2024;12:384.
11. Kim Y, Chang SW, Oh S. Buckling resistance, torque, and force generation during retreatment with D-RaCe, HyFlex Remover, and Mtwo retreatment files. Restor Dent Endod. 2023;48:e10.
12. Alelyani AA. Efficacy of solvent-free retreatment files with different flute designs in removing aged bioceramic sealer: a micro-CT study. Acta Bioeng Biomech. 2025;27:153-61.
13. Farrayeh A, Akil S, Eid A, Macaluso V, Mancino D, Haïkel Y, et al. Effectiveness of two endodontic instruments in calcium silicate-based sealer retreatment. Bioengineering (Basel). 2023;10:362.
14. Gu LS, Ling JQ, Wei X, Huang XY. Efficacy of ProTaper Universal rotary retreatment system for gutta-percha removal from root canals. Int Endod J. 2008;41:288-95.
15. Srirama S, Chandrasekaran S, Arul B, Natanasabapathy V. Comparative evaluation of removal of gutta percha and bioceramic sealer using EdgeFile-XR and ProTaper Universal Retreatment files: micro-computed tomography study. Aust Endod J. 2025;51:358-68.
16. Willie C. Dissolving efficacy of xylene on epoxy resin-based and bioceramic-based root canal sealers. Sci Dent J. 2022;6:32-5.
17. Arora T, Dahiya S, Khandelwal S, Kaushik M, Qureshi Z. Decoding dissolution – solubility comparison of bioceramic-coated and conventional gutta-percha cones across solvents and two different time intervals: an in vitro study. J Contemp Dent Pract. 2025;26:639-44.